1

1

SERIE 66


THREAD SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

  • Resolution up to 10.000 pulses per turn
  • External diameter 58 mm
  • Eje roscado M8
  • Protection class IP64 according to DIN EN 60529
  • Anti-rotation system through flexible flange or antiturn stick
  • Connection by cable (other cable lenght available) or industrial connector M16

 

 

MECHANICAL SPECIFICATIONS
Materials – Cover: Aluminium
– Housing: Aluminium
– Shaft: Stainless Steel
Bearings Ballraces
Bearings lifetime 1×1010 rev.
Housing fixing Flexible flange 90.1027 (assembled)
Flexible flange 90.1045 (assembled)
Anti-turn stick 90.1041 (self-assembly kit included)
Permitted misalignment ±0.5 mm axial, ±0.3 mm radial (90.1027, 90.1045, 90.1041)
Maximum number of revolutions permitted mechanically 6000 rpm
Protection against dust and splashes according to DIN EN 60529 IP64
Rotor inertia moment 30 gcm2
Starting torque at 20ºC (68ºF) ≤ 0,02 Nm
Maximum load permitted on axial shaft 40 N
Maximum load permitted on radial shaft 60 N
Weight aprox. 0,5 Kg
Operating temperature range -20°C to +80°C – Standard
-40°C to +80°C – Special Customer UT00
Vibration according to DIN EN 60068-2-6 100 m/s2 (10Hz…2000Hz)
Shock according to DIN EN 60068-2-27 1000 m/s2 (6ms)
Maximum pulses per turn 10.000
Radial connection 2 meters cable or industrial connector M16 (other cable lenghts available on order)
Female connector not included

OUTPUT SIGNALS
OUTPUT CIRCUIT NPN Open Collector Push-Pull
Diff erenti al
RS422
(TTL compati ble)
RS422
(TTL compati ble)
Power supply 11…30 VDC 11…30 VDC 5 VDC ±10% 11…30 VDC
Output voltage 11…30 VDC 11…30 VDC 5 VDC 5 VDC
Consumption 40 mA Tipical: 45 mA
Max: 150 mA
Tipical: 70 mA
Max: 150 mA
Tipical: 80 mA
Max: 160 mA
Max. load capability / channel 40 mA ±30 mA ±20 mA ±20 mA
Lenght of cable allowed 50 m (24 VDC) 100 m 1200 m 1200 m
“Low” signal level VOL < 0.4 VDC (24 VDC) VOL < 2.5 VDC VOL < 0,5 VDC VOL < 0,5 VDC
“High” signal level VOH > 22 VDC (24 VDC) VOH > Vcc – 3 VDC VOH > 2.5 VDC VOH > 2.5 VDC
Frequency 100 kHz 200 kHz 300 kHz 300 kHz
Short circuit protection Not permanent Yes Yes Yes
Protection polarity inversion Yes Yes Not permanent Yes
Channel B leads (90° electric) channel A, view from the shaft, shaft rotating clockwise